battery power storage

From Noah.org
Revision as of 01:05, 18 June 2014 by Root (talk | contribs)
Jump to navigationJump to search


A custom battery pack should have thermal protection to prevent cell damage or rupture during charging or discharging. The standard is to use an NTC thermistor 10K/25. That is, R25°C=10KΩ, and B=3950. Note that 25°C=298.15°K. To calculate temperature from resistance, T = B / (ln(R/r)).